TurboMax RT Pro
Real Time PCR
Pro = Industry Leading Ramping Rate upto 8* C
6 Channel Detection - Multiplexing
6 Channel Detection - Multiplexing
TurboMax RT Pro is a high-throughput real-time PCR instrument. It adheres to the principles of high efficiency and quality, combined with the advanced temperature control system and optical system, as well as powerful software analysis functions. It can realize applications such as qualitative/quantitative analysis, genotyping allele identification, HRM, melting curve analysis and etc. The product adopts side scan technology, and all channels are collected at the same time. 96 samples can be scanned within 5 seconds to save the test time. This product has powerful software and hardware functions to meet the different needs.
APPLICATION
- Scientific Research - Research institutions and molecular clones, gene expression, and genotyping of various colleges and universities
- Clinical Diagnosis - Medical institutions perform pathogen testing, genetic screening, various infectious diseases, tumor diagnosis, etc.
- Animal Husbandry, agriculture - Environmental testing, pesticide residues and soil testing
- Pet Medical - Detectives of various pet pathogens (such as avian influenza, foot -and -mouth disease, swine fever, etc.) and health monitoring
- Food Safety - All kinds of food microbial detection, allergens, genetically modified food, real and false meat identification, etc.
- In Vitro Diagnosis - Reagent development, verification, regeneration drugs, etc.
TECHNICAL PARAMETERS
Model/Specification | |
---|---|
Model No. | TurboMax RT Pro |
Capacity | 96 well, 12x8 strip, 96x0.2ml single tube |
Formats | 0.2ml tube, 0.2ml 8-tube strips, 0.2ml 96 well plate |
Reaction Volume | 10-100ul |
Temperature Control Performance | |
---|---|
Temperature Range | 0-100°C |
MAX. Ramp Rate | 8°C |
Temp. Fluctuation | <±0.1°C |
Uniformity | <±0.2°C |
Accuracy | <±0.1°C | Gradient Spreed | 0.1-42°C |
Hot Lid Temperature | 30°C-110°C (Adjustable, default 105 °C) |
Temperature Control | Block/Tube |
Optical Performance | |
---|---|
Excitation Wavelength | 300–810 nm |
Emission Wavelength | 500–810 nm |
Detection Channel | 6 channel |
Detection Method | All channels scan at the same time |
Scan Period | 5 seconds to complete 96 well test |
Factory Calibrated Dyes |
F1: FAM/SYBR-Green/EVA-Green F2: HEX/VIC/JOE/TET/CY3/YELLOW F3: ROX/Texas Red F4: Cy5 |
Excitation Source | Long-life LED |
Detection Method | High sensitivity photoelectric detector |
Dynamic Range | 1–109 copies |
Sensitivity | 1 copy |
Control System | |
---|---|
Lid Operation | Automatic hot lid |
Feature Function | Qualitative/absolute quantification, relative quantification, genotyping, HRM, melting curve, standard curve, allele identification, temperature gradient function, etc. |
Data Management | Audit Trail System |
Operating System | Windows 7, Windows 10, Windows 11 |
Remote Monitoring | Can be connected to laboratory management system |
Data Export Formats | Excel, CSV, TXT, PDF |
Printing | Reports can be printed directly |
Control Method | 12.1-inch retractable color touch screen control or connect to computer control |
Communication | USB 2.0, RS232 |
Other Performance | |
---|---|
Dimension | 195 × 165 × 140 mm (L × W × H) |
Net Weight | 3 kg |
Voltage | 220 VAC, 50 Hz |
Power | DC 15 V, 150 W |
We Shall Ensure You Always get the Best Results
- Strong fluorescence signal, low background noise and high sensitivity.
- 96 samples 6 fluorescent channels are scaned within 5S.
- LED light source has the advantage of energy saving, environmental protection, long service life and maintenance free.
- Automatic hot lid, which can be used with automated workstations to improve work efficiency
- With 12.1-inch LCD touchscreen, real-time monitoring of operating conditions.
- Powerful software analysis functions can perform qualitative/quantitative analysis, high -resolution melting curve, genetic typing, relative quantitative, temperature gradient function, etc.